Testing of Different IT Products
Our IT Equipment Test Laboratory is fully equipped with proper machinery and modernized intruments. All the tests are done under supreme guidance and with proper safety and precautions. All the laboratory environment requirements are fulfilled as per the concern standards.
Testing Facilities and Products
Delhi Test House offers one stop solution for testing of all DIETY(Department of Electronics and Information Technology) notified products to meet the growing demand for IT and customer electronic products where manufacturers need faster, accurate, and efficient services to meet the requirement as per Indian/International Standards.
Products:
Visual Display Unit |
Laptop/ Notebook |
Tablets |
Printer / Plotters |
Video monitor / LCD / LED / Plasma TV’s |
Automated data processing machine |
Scanner |
Wireless Keyboards |
Set Top Boxes |
Telephone Answering Machine |
Power adaptors for IT equipment |
Mobile Phones |
Cash register |
Point of sale terminal |
Copying Machines / Duplicators |
Smart card readers |
Mail Processing Machines / Postage Machines / Franking machines |
Passport Reader |
Power Banks for use in portable applications |
Discrete Graphic Processing Unit (GPU) |
Integrated Desktop Computer |
Small scale servers with Ethernet |
Testing Parameters | Test Method |
---|---|
Components | IS 13252 (Part 1), IEC 60950-1 (Clause. 1.5) |
Input current | IS 13252 (Part 1), IEC 60950-1 (Clause. 1.6.2) |
Marking and instructions | IS 13252 (Part 1), IEC 60950-1 (Clause. 1.7) |
Durability | IS 13252 (Part 1), IEC 60950-1 (Clause. 1.7.11) |
Access to energized parts | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.1.1) |
Access to ELV wiring | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.1.1.3) |
Energy Hazard | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.1.1.5) |
Discharge of capacitors in equipment | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.1.1.7) |
SELV circuits | IS 13252 (Part 1), IEC 60950-1 (Clause. -2.2) |
TNV circuits Limits | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.3.1) |
Connection of TNV circuits to other circuits | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.3.4) |
Limited current circuits Limits values & Limited power sources | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.4.2) & (Clause. 2.5) |
Size of protective Earthing & bonding conductor | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.6.3.2/2.6.3.3) |
Resistance of Earthing conductors and their terminals | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.6.3.4) |
Protection requirement for safety interlocks | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.8.2) |
Humidity conditioning | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.9.2) |
Clearances | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.10.3) |
Creepage distance | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.10.4) |
Thermal conditioning | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.10.8.2) |
Thermal cycling | IS 13252 (Part 1), IEC 60950-1 (Clause. 2.10.9) |
Wiring connections & supply | IS 13252 (Part 1), IEC 60950-1 (Clause. 3.0) |
Stability | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.1) |
Mechanical Strength | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2) |
Steady force Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2.2, 4.2.3, 4.2.4) |
Impact Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2.5) |
Drop Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2.6) |
Stress relief Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2.7) |
Mechanical strength for Wall or ceiling mounted equipment | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.2.10) |
Design & construction for Handles & manual Controls | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.3.2) |
Protection against Hazardous moving parts | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.4) |
Temperature Tests | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.5.2) |
Resistance to abnormal heat | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.5.5) |
Opening in enclosure | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.6) |
Evaluation measures for larger opening | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.6.4.2) |
Resistance to fire | IS 13252 (Part 1), IEC 60950-1 (Clause. 4.7) |
Touch current & protective conductor current | IS 13252 (Part 1), IEC 60950-1 (Clause. 5.1) |
Electric strength | IS 13252 (Part 1), IEC 60950-1 (Clause. 5.2) |
Protection from Hazardous voltages | IS 13252 (Part 1), IEC 60950-1 (Clause. 6.1.1) |
Separation of the telecommunication network from Earthing | IS 13252 (Part 1), IEC 60950-1 (Clause. 6.1.2) |
Impulse Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 6.2.2.1) |
Steady state Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 6.2.2.2) |
Compliance criteria | IS 13252 (Part 1), IEC 60950-1 (Clause. 6.2.2.3) |
Voltage Surge Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 7.4.2) |
Impulse Test | IS 13252 (Part 1), IEC 60950-1 (Clause. 7.4.3) |
Off mode | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Sleep Mode | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Idle State | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Active State | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Full Load | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Active Mode power consumption for single Output power supply | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Active Mode power consumption for multiple Output power supply | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |
Standby Mode Power consumption | DTH-K/SOP/ ELECT/ 10 DTH-K/SOP/ ELECT/ 11 (Based on ENERGY STAR, BEE Schedule 14 Version 2&5) |